Call us

Can Heat Lock Help Warehouses Aim for Below 38°C Indoors in India?

Floorzy Heat Lock • India-wide warehouse cooling guide

Can Heat Lock Help Warehouses Aim for Below 38°C Indoors in India?

Want your factory or warehouse indoor air to stay below 38°C? That is a performance goal to assess and measure, not a temperature Floorzy can promise for every building. Explore how Heat Lock can reduce solar heat gain through suitable metal roofs, what Floorzy has actually reported, and how to evaluate the outcome at working height.

Target: below 38°C indoorsGI and metal-sheet roofsIndia-wide enquiries
Illustration of warehouse indoor air temperature: 45 degrees Celsius without Heat Lock versus below 38 degrees Celsius as a target with Floorzy Heat Lock
Illustrative indoor warehouse comparison: 45°C without Heat Lock versus a desired temperature below 38°C. This is a project goal, not verified before-and-after results or a guaranteed Heat Lock temperature. Actual indoor outcomes depend on weather, roof condition, ventilation and internal heat sources.
Quick answer: indoor warehouse temperature

Below 38°C indoors is a proposed warehouse performance target, not a demonstrated Heat Lock guarantee. Heat Lock can reduce solar heat absorption at a suitable roof, but whether warehouse air stays below 38°C depends on ventilation, outdoor weather, occupancy and internal machinery heat. Floorzy reports an indoor change from 49°C to 41°C at head height at one Peenya facility. Its separate up to 15°C claim refers to roof-surface temperature. Learn how to check indoor results.

<38°CDesired indoor temperature target; not guaranteed
8°CIndoor reduction Floorzy reports at its Peenya project
5–10°CIndicative indoor reduction published by Floorzy; site-dependent
Up to 15°CSeparate roof-surface temperature claim, not indoor air
Understanding the problem

Why Do Warehouses Get So Hot Inside Under Metal Sheet Roofs?

Across India, large factories and warehouses often use galvanised iron (GI), colour-coated steel or other metal-sheet roofing. These roofs are practical for wide-span industrial buildings, but solar radiation can heat their exposed surfaces during sunny hours. That heat can influence the roof’s underside, air movement and thermal comfort below.

The challenge varies across India’s climate zones. A manufacturing shed in Ahmedabad, a warehouse in Hyderabad, a workshop in Delhi NCR or a production unit in Chennai may face very different sunshine, humidity, ventilation and internal process loads. The right solution therefore begins with the roof material, its condition and the source of unwanted heat—not a single promised indoor temperature.

Government of India guidance on cool roofs explains that high solar reflectance and thermal emittance can limit roof solar heat gain. Reflective coatings help address heat entering from sunlight; they do not replace ventilation, process-heat extraction or insulation when those are also needed.

The Heat Lock approach

How Does Heat Lock Help Reduce Heat Entering Warehouses?

Heat Lock is described by Floorzy as a solar-reflective thermal-barrier coating for compatible industrial roofs. Its published specifications focus on two measurable optical properties rather than a vague “cool paint” label.

01

Solar reflectance

A published reflectance range of 0.65–0.80 means the coated surface is designed to reflect a substantial proportion of incoming solar energy. Actual performance depends on the formulation, application and ageing.

02

Thermal emittance

Floorzy publishes thermal emittance above 0.85, describing how efficiently the surface can release absorbed heat as thermal radiation.

03

Existing roof retrofit

For a structurally sound, compatible roof, the two-coat system can be considered without removing the entire metal roofing system. Preparation, access and compatibility must be assessed first.

Important: “Up to 15°C” refers to the roof-surface temperature difference measured under suitable direct-sun conditions. Indoor-air temperatures depend on ventilation, roof geometry, insulation, weather and internal machinery.
A measurable goal, not a universal promise

Can a Warehouse Be Kept Below 38°C Indoors After Heat Lock?

Below 38°C can be a project target only after reviewing the building and agreeing how performance will be tested. A heat-reflective coating tackles part of the incoming roof heat; it cannot directly control outdoor air, hot production processes or insufficient ventilation.

For example, if a warehouse currently measures 45°C indoor air, bringing it to under 38°C would require more than 7°C of indoor reduction in comparable conditions. That comparison is illustrative, not proof that Heat Lock alone will provide it. A target closer to 30°C indoors would be even more demanding and may need roof insulation, ventilation or mechanical cooling in addition to a reflective coating.

Ask Floorzy to assess the roof and record indoor temperatures at fixed occupied-area locations before and after work. Agree on the weather conditions, time of day, operating equipment, measurement period and what happens if the chosen target is not achieved. The separately documented Peenya project reached 41°C indoors after treatment, which is above the proposed 38°C ceiling.

Measure what matters inside

How to Measure Heat Lock’s Effect Inside a Warehouse

An infrared thermometer pointing at the roof measures surface temperature. It does not establish the air temperature employees experience at the warehouse working level. For an indoor claim, use calibrated air-temperature data loggers and record results at comparable indoor positions, ideally with an untreated reference area or a well-controlled before-and-after measurement plan. The same warehouse can feel different at floor level, head height and near the roof.

  1. Record indoor air temperature before coating.Monitor at working height and, if relevant, near storage racks or mezzanines. Avoid direct sun, machinery exhaust and hot surfaces affecting the sensor.
  2. Record outdoor conditions and production heat loads.Note time, weather, roof exposure, ventilation and the type of equipment running in the building.
  3. Confirm the roof is suitable for coating.Floorzy should review the substrate, old paint, corrosion, access and application conditions before recommending Heat Lock.
  4. Measure indoor temperature again after application.Use the same indoor locations, instrument type and comparable operating and weather conditions. A multi-day comparison is more useful than one isolated reading.
  5. Compare indoor air results separately from roof readings.Maintain separate records for exterior metal-sheet temperature, roof underside and warehouse indoor air temperature. Agree in writing on any project-specific test or performance terms.

About the under-38°C target: If your current warehouse temperature is 45°C, keeping the occupied area below 38°C requires more than 7°C reduction in comparable conditions. These are planning figures, not Heat Lock test results. The actual Peenya project published by Floorzy reports 49°C to 41°C indoors.

Floorzy-reported example

Indoor Heat Reduction in Peenya: 49°C Before, 41°C After Heat Lock

Textile factory with GI-sheet roof • Peenya, Bengaluru

In Floorzy’s published project description, an approximately 18,000 sq. ft. GI-sheet roof was treated with a two-coat Heat Lock system. Floorzy reports measuring 49°C indoors before treatment and 41°C indoors after treatment at head height—an 8°C difference in the occupied space. The same account separately reports a 15°C reduction at the roof surface.

49°C → 41°CCompany-reported indoor air temperature
8°CCompany-reported indoor improvement
68°C → 53°CSeparate reported roof-surface temperatures

Source: Floorzy’s own published case study. Independent measurements, matched weather details and a full third-party report were not available in the reviewed material. Results from one project cannot be guaranteed for all warehouses.

Review the Floorzy Heat Lock system page and ask for a documented indoor-temperature assessment suited to your facility.

Applications

Which Industrial Roofs Can Be Considered for Heat Lock?

Floorzy’s product material lists GI sheet, pre-painted steel, asbestos-cement and concrete as potential substrates. Every roof still needs an assessment for structural soundness, compatibility and required preparation.

Roof or facilityPotential benefitCheck before application
GI / galvanised metal sheet roofReduce solar heat absorbed at exposed roofing surfacesRust, fasteners, coating adhesion and safe access
Pre-painted steel industrial shedImprove reflectance of an existing roof surfaceCompatibility with the existing paint and surface preparation
Warehouse / logistics roofAddress a large roof-related heat sourceRoof area, skylights, ventilation, stored goods and operations
Food processing / manufacturingPotentially reduce solar heat load entering the buildingProcess heat, ventilation and any sector-specific conditions
Existing asbestos-cement roofPotential cool-roof retrofit subject to professional reviewSpecialist safety and legal requirements; do not disturb or abrade asbestos-containing roofing
Concrete roofImprove surface reflectanceWaterproofing integrity, moisture, cracks and drainage
Compare the approach

Heat Lock vs Insulation, Ventilation and Ordinary Roof Paint

Heat Lock roof coating

Limits solar heat absorbed at the exterior roof surface, which may help lower indoor warehouse heat gain. Best considered for compatible existing roofs where solar exposure is a substantial problem and the customer wants a measurable surface-temperature demonstration.

Thermal insulation or insulated roof panels

Resist heat transfer through the roof assembly. These may be a better match when thermal resistance is the primary need or when replacing a roof is already planned.

Industrial ventilation and exhaust

Help remove heated air and process-generated heat. They can complement roof cooling, especially in buildings with ovens, furnaces, compressors or poorly ventilated production lines.

Ordinary light-coloured roof paint

Can also reflect solar radiation, but performance varies with coating chemistry, solar reflectance, thermal emittance, durability and maintenance. Ask for comparable technical data rather than assuming all white coatings behave alike.

For industrial buyers across India

Warehouse Indoor Heat Reduction Across India

The heat problem is not limited to Bengaluru. Factory owners and facility teams searching for metal-sheet roof cooling in the industrial regions below can use the same checklist: assess the roof, identify solar heat load, request a panel demonstration and compare results under similar conditions.

Delhi NCRAhmedabadSuratMumbaiPuneHyderabadBengaluruChennaiCoimbatoreKolkataNagpurJaipur

Availability note: Floorzy’s published Heat Lock service pages confirm application in Bengaluru and Karnataka. For projects elsewhere in India, contact the team to confirm survey availability, technical support and application arrangements before planning work. The cities above represent search and buyer markets, not verified local Floorzy branches.

Before you buy

Questions to Ask Any Roof-Cooling Contractor

What exactly is being measured?

For worker comfort, request indoor air-temperature readings at a consistent height; roof-surface and roof-underside readings are separate, supporting metrics, not substitutes.

Are the measurements comparable?

Use comparable indoor sensor placement, operating periods, outside temperature, ventilation status and working heat loads, ideally with a repeated or controlled comparison.

What are the surface preparation steps?

Confirm cleaning, corrosion treatment, repairs, safety access, substrate adhesion and whether any existing roof problems must be addressed first.

What will the written quotation include?

Clarify roof area, coating system, number of coats, preparation, access equipment, weather delays, maintenance and any verifiable performance assurance terms.

Frequently asked questions

Warehouse Indoor Temperature & Heat Lock FAQs

How much can Heat Lock reduce the temperature inside a warehouse?

Floorzy says indoor air temperature may reduce by approximately 5–10°C depending on the building, and reports an 8°C indoor change (49°C to 41°C) in a Peenya factory example. These are company claims and not guaranteed indoor outcomes for every warehouse.

Is a 15°C reduction guaranteed inside a warehouse?

No. Floorzy’s up-to-15°C claim relates to roof-surface temperature, and its current published FAQs do not guarantee that indoor air will become 15°C cooler. Any indoor performance assurance would need specific written terms and a consistent air-temperature measurement protocol.

Is Heat Lock a proven solution for reducing heat inside industrial sheds?

Heat-reflective roof coatings can reduce solar heat gain, but indoor outcomes depend on the building and ventilation. Floorzy reports one indoor improvement example, while broader independently published studies show results vary considerably. Ask for site-specific measurements rather than relying on a blanket promise.

Can Heat Lock guarantee indoor warehouse temperatures below 38°C?

No general below-38°C guarantee is supported by Floorzy’s published data. The 38°C ceiling is a suggested project target that requires an assessment and a documented testing agreement. Floorzy’s Peenya project reported 41°C indoors after treatment.

Can Heat Lock be applied to existing GI and steel roofing sheets?

GI and pre-painted steel are listed as compatible substrates by Floorzy, subject to roof condition, preparation, coating compatibility and safe access.

Can warehouse operations continue during installation?

External application may allow operations inside to continue, as reported for Floorzy’s Peenya case study. Actual work restrictions depend on access, site safety, roof condition and operating requirements.

How long does Heat Lock application take?

Floorzy’s product pages describe approximately one to two days for a typical mid-sized roof, subject to site size, preparation, access and weather. This is an indicative programme, not a fixed commitment.

Is Heat Lock available in Delhi, Mumbai, Hyderabad, Chennai and other Indian cities?

Floorzy publicly documents Bengaluru and Karnataka application coverage. Customers elsewhere in India can enquire directly to confirm local service, survey and project availability; nationwide application has not been independently verified.

How is Heat Lock different from ordinary white paint?

Heat Lock is marketed as a two-coat industrial roof system with published solar reflectance and thermal emittance. White coatings can also reflect solar radiation, so request technical data and ageing/maintenance evidence for a fair comparison.

Can Heat Lock replace roof repairs, insulation or factory exhaust systems?

No. Significant roof damage needs appropriate repair. Insulation and ventilation solve related but different problems, and internal equipment-generated heat may require dedicated extraction.

Floorzy Makeover • Heat Lock

Focus on Cooler Air Inside Your Warehouse.

Is your warehouse uncomfortable during hot afternoons? Ask Floorzy for a roof assessment and an indoor-air temperature measurement plan, as well as a suitable roof-coating quotation. Do not rely only on a roof-surface thermometer to judge worker comfort. For projects beyond Karnataka, confirm current service availability with the team.

Leave a Comment

Your email address will not be published. Required fields are marked *